PUSH WIRE Installer Connectors from WAGO

773 Series Connector

Technical Data

2-, 4-, 6- & 8-conductor

0.75 - 2.5mm2 "s"
1.75 - 2.5mm2 "st"
400V/4 kV/2
24A

Strip length 12mm
"s" solid, "st" stranded conductors

3-conductor

2.5 - 6mm2 "s + st"
400V/4 kV/2
41A

Strip length 12 - 13mm
"s" solid, "st" stranded conductors

Single pole commoning connector

773 Series Operating Instructions & Part Numbers 

 
de.espirit.firstspirit.access.editor.value.DomElementImpl@617b06a9

1. Strip Insulation

12mm.

de.espirit.firstspirit.access.editor.value.DomElementImpl@50846935

2. Insert

Push the conductor fully into the housing to complete the connection.

de.espirit.firstspirit.access.editor.value.DomElementImpl@6c7ceded

3. Remove

Simply twist and pull the connector and conductor at the same time.

de.espirit.firstspirit.access.editor.value.DomElementImpl@1daebf1c

Test Point

On the back of the housing.

+
773-102, 2-con PUSH WIRE Connector (PU 100)
+
773-104, 4-con PUSH WIRE Connector (PU 100)
+
773-106, 6-con PUSH WIRE Connector (PU 50)
+
773-108, 8-con PUSH WIRE Connector (PU 50)
+
773-173, 3-con PUSH WIRE Connector (PU 50)

224 Series Lighting Connector

Technical Data

Installation side:- 1 - 2.5mm2 "s"
Lighting side:- 0.5 - 2.5mm2 "s + f-st"
400V/4 kV/2
24A

Strip length 9 - 11mm
"s" solid and "f-st" fine stranded conductors

Single pole commoning connector

224 Series Operating Instructions & Part Numbers 

 
de.espirit.firstspirit.access.editor.value.DomElementImpl@17719acb

1. Strip Insulation

both conductors 9 - 11mm.
2. Insert - Insulation Side
Push the solid conductor fully into the installation side to complete the connection.

de.espirit.firstspirit.access.editor.value.DomElementImpl@36b02d6b

3. Insert - Lighting Side

Squeeze together the housing and insert the conductor fully, then release to complete the connection.

de.espirit.firstspirit.access.editor.value.DomElementImpl@708c634f

4. Remove

For the Insulation side simply twist and pull the conductor at the same time. To remove the lighting side squeeze together the housing and pull out the conductor.

de.espirit.firstspirit.access.editor.value.DomElementImpl@3c5d32f9

Test Point

On the bottom of the housing.

+
224-101, 2-con Lighting Connector (PU 100)
+
224-112, 3-con Lighting Connector (PU 100)
+
224-201, 2-con Service Connector (PU 50)

243 Series Micro Connector

Technical Data

0.6 - 0.8mm Ø "s"
100V/1.5 kV/2
6A

Strip length 5 - 6mm
"s" solid conductors

Single pole commoning connector

243 Series Operating Instructions & Part Numbers 

 
de.espirit.firstspirit.access.editor.value.DomElementImpl@71b62b22

1. Strip Insulation

5 - 6mm.

de.espirit.firstspirit.access.editor.value.DomElementImpl@7d6e26f0

2. Insert

Push the conductor fully into the housing to complete the connection.

de.espirit.firstspirit.access.editor.value.DomElementImpl@6688928d

Test Point

On the front of the housing.

de.espirit.firstspirit.access.editor.value.DomElementImpl@69ba97bc

KNX Applications

The 243-211 can be used within KNX applications.

+
243-204, 4-con Micro PUSH WIRE Connector (PU 100)
+
243-804, 4-con Micro PUSH WIRE Connector (PU 100)
+
243-304, 4-con Micro PUSH WIRE Connector (PU 100)
+
243-504, 4-con Micro PUSH WIRE Connector (PU 100)
+
243-208, 8-con Micro PUSH WIRE Connector (PU 50)
+
243-808, 8-con Micro PUSH WIRE Connector (PU 50)
+
243-308, 8-con Micro PUSH WIRE Connector (PU 50)
+
243-508, 8-con Micro PUSH WIRE Connector (PU 50)

Contact

Contact us on 01788 568 008
Sales:
uksales@wago.com
Technical:
ukmarketing@wago.com

Data Sheet

1

Data Sheet

1

Data Sheet

1